Search results
Results from the WOW.Com Content Network
ANSI/ASHRAE Standard 55: Thermal Environmental Conditions for Human Occupancy is an American National Standard published by ASHRAE that establishes the ranges of indoor environmental conditions to achieve acceptable thermal comfort for occupants of buildings. It was first published in 1966, and since 2004 has been updated every three to six years.
The recommended level of indoor humidity is in the range of 30–60% in air conditioned buildings, [34] [35] but new standards such as the adaptive model allow lower and higher humidity, depending on the other factors involved in thermal comfort. Recently, the effects of low relative humidity and high air velocity were tested on humans after ...
In certain fields, like science and engineering, and within a particular context, room temperature can mean different agreed-upon ranges. In contrast, ambient temperature is the actual temperature, as measured by a thermometer, of the air (or other medium and surroundings) in any particular place. The ambient temperature (e.g. an unheated room ...
Operative temperature is used in heat transfer and thermal comfort analysis in transportation and buildings. [10] Most psychrometric charts used in HVAC design only show the dry bulb temperature on the x-axis(abscissa), however, it is the operative temperature which is specified on the x-axis of the psychrometric chart illustrated in ANSI/ASHRAE Standard 55 – Thermal Environmental Conditions ...
And as one 2023 study demonstrates, for adults who typically sleep with room temperatures between 68 and 77 degrees Fahrenheit, increasing the temperature to between 77 and 86 degrees Fahrenheit ...
The ideal temperature for sleep is typically between 60°F and 67°F for most adults, says Martina Vendrame, M.D., neurologist and sleep medicine specialist at Lehigh Valley Health Network.
ASHRAE 90.1 follows a similar path of development and revision. [6] Though ASHRAE 90.1 is revised and published every three years just like the IECC, people can submit interim revisions at any time within this period. [5] ASHRAE has a standards committee that manages the process, and votes on the final versions of the energy code. [5]
The concept of mean radiant temperature (MRT) is used to quantify the exchange of radiant heat between a human and their surrounding environment, with a view to understanding the influence of surface temperatures on personal comfort. Mean radiant temperature has been both qualitatively defined and quantitatively evaluated for both indoor and ...