enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. VLF cable testing - Wikipedia

    en.wikipedia.org/wiki/VLF_cable_testing

    The test is typically performed over a range of test voltages from 0.5 Uo to 2 Uo depending on the standard/guide that is being followed. Apply VLF in order to detect and measure partial discharge . In this case, the IEEE 400.3 outlines a procedure for assessment and IEC 60270 provides the background for partial discharge testing of high ...

  3. List of IEC standards - Wikipedia

    en.wikipedia.org/wiki/List_of_IEC_standards

    IEC 60172 Test procedure for the determination of the temperature index of enamelled and tape wrapped winding wires; IEC 60183 Guidance for the selection of high-voltage A.C. cable systems; IEC 60188 High-pressure mercury vapour lamps – Performance specifications; IEC 60189 Low-frequency cables and wires with PVC insulation and PVC sheath

  4. Cross-linked polyethylene - Wikipedia

    en.wikipedia.org/wiki/Cross-linked_polyethylene

    A cross-linked polyethylene (PEX) pipe. Cross-linked polyethylene, commonly abbreviated PEX, XPE or XLPE, is a form of polyethylene with cross-links.It is used predominantly in building services pipework systems, hydronic radiant heating and cooling systems, domestic water piping, insulation for high tension (high voltage) electrical cables, and baby play mats.

  5. High-voltage cable - Wikipedia

    en.wikipedia.org/wiki/High-voltage_cable

    High voltage is defined as any voltage over 1000 volts. [3] Those of 2 to 33 kV are usually called medium voltage cables, those over 50 kV high voltage cables.. Modern HV cables have a simple design consisting of a few parts: the conductor, the conductor shield, the insulation, the insulation shield, the metallic shield, and the jacket.

  6. Cable fault location - Wikipedia

    en.wikipedia.org/wiki/Cable_fault_location

    Murray loop test employs the principle of wheatstone bridge for locating the fault. To perform this test, it is necessary to have a sound cable running alongside the faulty cable. One end of the faulted cable is connected through a pair of resistors to the voltage source. Also a null detector is connected. The other end of the cable is shorted.

  7. Thermoplastic-sheathed cable - Wikipedia

    en.wikipedia.org/wiki/Thermoplastic-sheathed_cable

    Prior to 2013 IS 201-4:2001 ( I.S. 201 part 4: PVC and Low Smoke Halogen Free Sheathed cables for fixed wiring) permitted both the UK style of twin and earth, and also a version with a CPC with a cross-section equal to that of the main conductors and insulated in green and yellow inside the full length of the cable.

  8. Tri-rated cable - Wikipedia

    en.wikipedia.org/wiki/Tri-rated_cable

    BS 6231 is a British Standard, last revised in 2006 by the BSI Group. [4] This standard specifies the performance and construction requirements of electrical cables that are single core, non-sheathed, PVC-insulated and rated 600/1000 V. Wire meeting the requirements of type CK of this standard is used as tri-rated wire.

  9. Dielectric withstand test - Wikipedia

    en.wikipedia.org/wiki/Dielectric_withstand_test

    In electrical engineering, a dielectric withstand test (also pressure test, high potential test, hipot test, or insulation test) is an electrical safety test performed on a component or product to determine the effectiveness of its insulation. The test may be between mutually insulated sections of a part, or energized parts and ground.