Search results
Results from the WOW.Com Content Network
A phase frequency detector (PFD) is an asynchronous circuit originally made of four flip-flops (i.e., the phase-frequency detectors found in both the RCA CD4046 and the motorola MC4344 ICs introduced in the 1970s). The logic determines which of the two signals has a zero-crossing earlier or more often.
A phase detector characteristic is a function of phase difference describing the output of the phase detector. For the analysis of Phase detector it is usually considered the models of PD in signal (time) domain and phase-frequency domain. [1] In this case for constructing of an adequate nonlinear mathematical model of PD in phase-frequency ...
Phase-frequency detector dynamics. Phase-frequency detector (PFD) is triggered by the trailing edges of the reference (Ref) and controlled (VCO) signals. The output signal of PFD () can have only three states: 0, +, and .
Ion mobility spectrometry–mass spectrometry (IMS-MS) is an analytical chemistry method that separates gas phase ions based on their interaction with a collision gas and their masses. In the first step, the ions are separated according to their mobility through a buffer gas on a millisecond timescale using an ion mobility spectrometer .
By itself, the signal beam's energy flux, , is DC and thus erases the phase associated with its optical frequency; Heterodyne detection allows this phase to be detected. If the optical phase of the signal beam shifts by an angle phi, then the phase of the electronic difference frequency shifts by exactly the same angle phi.
THz-TDS measures the electric field of a pulse and not just the power. Thus, THz-TDS measures both the amplitude and phase information of the frequency components it contains. In contrast, measuring only the power at each frequency is essentially a photon counting technique; information regarding the phase of the light is not obtained.
This is either done by driving the sensor with the deflection signal phase shifted by 90°, or by using an advanced phase-locked loop which can lock to a specific phase. [4] The microscope can then use the change in resonant frequency ( Δ {\displaystyle \Delta } f) as the SPM reference channel, either in feedback mode , or it can be recorded ...
The mechanism of detection is based on the adsorbing molecules causing changes in the local index of refraction, changing the resonance conditions of the surface plasmon waves. The same principle is exploited in the recently developed competitive platform based on loss-less dielectric multilayers ( DBR ), supporting surface electromagnetic ...