Search results
Results from the WOW.Com Content Network
However, AWG is dissimilar to IEC 60228, the metric wire-size standard used in most parts of the world, based directly on the wire cross-section area (in square millimetres, mm 2). The AWG tables are for a single, solid and round conductor. The AWG of a stranded wire is determined by the cross-sectional area of the equivalent solid conductor.
Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...
The conversion factor from square mils to circular mils is therefore 4/ π cmil per square mil: 4 π c m i l m i l 2 . {\displaystyle {\rm {{\frac {4}{\pi }}{\frac {cmil}{mil^{2}}}.}}} The formula for the area of an arbitrary circle in circular mils can be derived by applying this conversion factor to the standard formula for the area of a ...
The Birmingham gauge ranges from 5/0 or 00000, the lowest gauge number corresponding to the largest size of 0.500 inches (12.7 mm), to 36, the highest gauge number corresponding to the smallest size of 0.004 inches (0.10 mm). The increments between gauge sizes are not linear and vary. [2]
Six series are covered in one of TE's catalogs (which omits the 0.375 in/9.5 mm, but mentions it elsewhere), named after their blade width in mils. [3] Insulated versions of the terminals are color-coded to indicate what wire gauges they may be used with.
Cross-sectional area of a mechanical pencil lead (0.5-0.7 mm in diameter) [16] 10 −6: 1 square millimetre (mm 2) 1–2 mm 2: Area of a human fovea [17] 2 mm 2: Area of the head of a pin: 10 −5 30–50 mm 2: Area of a 6–8 mm hole punched in a piece of paper by a hole punch [18] 10 −4: 1 square centimetre (cm 2) 290 mm 2: Area of one side ...
By default, the output value is rounded to adjust its precision to match that of the input. An input such as 1234 is interpreted as 1234 ± 0.5, while 1200 is interpreted as 1200 ± 50, and the output value is displayed accordingly, taking into account the scale factor used in the conversion.
Conversions between units in the metric system are defined by their prefixes (for example, 1 kilogram = 1000 grams, 1 milligram = 0.001 grams) and are thus not listed in this article. Exceptions are made if the unit is commonly known by another name (for example, 1 micron = 10 −6 metre).