Search results
Results from the WOW.Com Content Network
Nominal Pipe Size (NPS) is a North American set of standard sizes for pipes used for high or low pressures and temperatures. [1] " Nominal" refers to pipe in non-specific terms and identifies the diameter of the hole with a non-dimensional number (for example – 2-inch nominal steel pipe" consists of many varieties of steel pipe with the only criterion being a 2.375-inch (60.3 mm) outside ...
A tube and pipe may be specified by standard pipe size designations, e.g., nominal pipe size, or by nominal outside or inside diameter and/or wall thickness. The actual dimensions of pipe are usually not the nominal dimensions: A 1-inch pipe will not actually measure 1 inch in either outside or inside diameter, whereas many types of tubing are ...
The need for the hydraulic diameter arises due to the use of a single dimension in the case of a dimensionless quantity such as the Reynolds number, which prefers a single variable for flow analysis rather than the set of variables as listed in the table below. The Manning formula contains a quantity called the hydraulic radius.
Plastic Pipe lengths manufactured in Australia by extruding HDPE material.. Plastic pipe is a tubular section, or hollow cylinder, made of plastic.It is usually, but not necessarily, of circular cross-section, used mainly to convey substances which can flow—liquids and gases (fluids), slurries, powders and masses of small solids.
Standard dimension ratio (SDR) is a method of rating a pipe's durability against pressure. The standard dimension ratio describes the correlation between the pipe dimension and the thickness of the pipe wall. [1] Common nominations are SDR11, SDR17, SDR26 and SDR35. Pipes with a lower SDR can withstand higher pressures.
FMT is a raceway, but not a conduit and is described in a separate NEC Article 360. It only comes in 1/2" & 3/4" trade sizes, whereas FMC is sized 1/2" ~ 4" trade sizes. NEC 360.2 describes it as: "A raceway that is circular in cross section, flexible, metallic and liquidtight without a nonmetallic jacket."
It must be eliminated using radii whenever is possible. It is recommended that an inside radius be a minimum of one times the thickness. At corners, the suggested inside radius is 0.5 times the material thickness and the outside radius is 1.5 times the material thickness. A bigger radius should be used if part design allows
Prior to 2013 IS 201-4:2001 ( I.S. 201 part 4: PVC and Low Smoke Halogen Free Sheathed cables for fixed wiring) permitted both the UK style of twin and earth, and also a version with a CPC with a cross-section equal to that of the main conductors and insulated in green and yellow inside the full length of the cable.