enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Fraction of inspired oxygen - Wikipedia

    en.wikipedia.org/wiki/Fraction_of_Inspired_Oxygen

    Example calculation After drawing an arterial blood gas sample from a patient the P a O 2 is found to be 100 mmHg. Since the patient is receiving oxygen-saturated air resulting in a F I O 2 of 50% oxygen his calculated P a O 2 /F I O 2 ratio would be 100 mmHg/0.50 = 200 mmHg.

  3. Oxygenation index - Wikipedia

    en.wikipedia.org/wiki/Oxygenation_index

    The oxygenation index is a calculation used in intensive care medicine to measure the fraction of inspired oxygen (FiO2) and its usage within the body. A lower oxygenation index is better - this can be inferred by the equation itself. As the oxygenation of a person improves, they will be able to achieve a higher PaO2 at a lower FiO2.

  4. AIDA interactive educational freeware diabetes simulator

    en.wikipedia.org/wiki/AIDA_interactive...

    More than 1,075,000 diabetes simulations have been run via a web-based version of the AIDA diabetes simulator. The AIDA software is intended to serve as an educational support tool and can be used by anyone — person with diabetes, relative of a patient, health care professional (doctor, nurse, clinical diabetes educator, dietician, pharmacist ...

  5. Horowitz index - Wikipedia

    en.wikipedia.org/wiki/Horowitz_index

    This is calculated by dividing the PaO2 by the FiO2. Example: patient who is receiving an FiO2 of .5 (i.e., 50%) with a measured PaO2 of 60 mmHg has a PaO 2 /FiO 2 ratio of 120. In healthy lungs, the Horowitz index depends on age and usually falls between 350 and 450.

  6. Hypoxic Training Index - Wikipedia

    en.wikipedia.org/wiki/Hypoxic_Training_Index

    The values of SpO2 above 89% are not considered in the calculation of HTi, as such saturation levels do not contribute to the treatment. SpO2 values below 75% count as 75%. HTi is calculated as an integral value of SpO2 readings made with 1 s sampling frequency and divided by 60 in order to produce a “per minute” value.

  7. Homeostatic model assessment - Wikipedia

    en.wikipedia.org/wiki/Homeostatic_model_assessment

    The HOMA authors used data from physiological studies to develop mathematical equations describing glucose regulation as a feedback loop. [1] They published computer software that solves the equations, so that insulin resistance and β-cell function can be estimated from fasting glucose and insulin levels.

  8. Alveolar gas equation - Wikipedia

    en.wikipedia.org/wiki/Alveolar_gas_equation

    The partial pressure of oxygen (pO 2) in the pulmonary alveoli is required to calculate both the alveolar-arterial gradient of oxygen and the amount of right-to-left cardiac shunt, which are both clinically useful quantities. However, it is not practical to take a sample of gas from the alveoli in order to directly measure the partial pressure ...

  9. Diabetes management software - Wikipedia

    en.wikipedia.org/wiki/Diabetes_management_software

    Conducting regular self-management tasks such as medication and insulin intake, blood sugar checkup, diet observance, and physical exercise are really demanding. [1] This is why the use of diabetes-related apps for the purposes of recording diet and medication intake or blood glucose level is promising to improve the health condition for the patients. [2]