enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Fire sprinkler system - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler_system

    For example, in an office building classified as light hazard, a typical design area would be 1,500 square feet (140 m 2) and the design density would be 0.1 US gallons per minute (0.38 L/min) per 1 square foot (0.093 m 2) or a minimum of 150 US gallons per minute (570 L/min) applied over the 1,500-square-foot (140 m 2) design area

  3. K-factor (fire protection) - Wikipedia

    en.wikipedia.org/wiki/K-factor_(fire_protection)

    Toggle the table of contents. K-factor (fire protection) Add languages. Add links. Article; Talk; English. ... This page was last edited on 13 August 2024, at 15:57 ...

  4. Hydraulic calculation - Wikipedia

    en.wikipedia.org/wiki/Hydraulic_calculation

    The hydraulic calculation procedure is defined in the applicable reference model codes such as that published by the US-based National Fire Protection Association (NFPA), [2] or the EN 12845 standard, Fixed firefighting system – Automatic sprinkler systems – Design, installation and maintenance. [3]

  5. Fire sprinkler - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler

    The 2002 edition of the NFPA #13 standard, section 3.6.1 defines quick response sprinklers as having a response time index (RTI) of 50 (meter-seconds) 1/2 or less. RTI is a measure of how thermally responsive the heat-responsive element of the sprinkler is, measured as the time needed to raise the temperature of the sprinkler bulb to 63% of the ...

  6. National Fire Protection Association - Wikipedia

    en.wikipedia.org/wiki/National_Fire_Protection...

    The committee's initial report evolved into NFPA 13, Standard for the Installation of Sprinkler Systems, the most widely used fire sprinkler standard. [ 6 ] Around 1904, the NFPA began to expand its membership from affiliates of fire insurance companies to many other organizations and individuals, and also expanded its mission beyond ...

  7. NEMA enclosure types - Wikipedia

    en.wikipedia.org/wiki/NEMA_enclosure_types

    Submersible. Design depends on specified conditions of pressure and time; submersible in water or oil; used in quarries, mines, and manholes. 7: Certified and labelled for use in areas with specific hazardous conditions: for indoor use in Class I, Groups A, B, C, and D environments as defined in NFPA standards such as the NEC. 8

  8. These are the best Cyber Monday deals under $100: Walmart ...

    www.aol.com/lifestyle/cyber-monday-deals-under...

    Cyber Monday savings are on fire. We found the top deals you can shop under $100, including Disney+, Amazon devices, toys, and more.

  9. Hazen–Williams equation - Wikipedia

    en.wikipedia.org/wiki/Hazen–Williams_equation

    It is used in the design of water pipe systems [1] such as fire sprinkler systems, [2] water supply networks, and irrigation systems. It is named after Allen Hazen and Gardner Stewart Williams. The Hazen–Williams equation has the advantage that the coefficient C is not a function of the Reynolds number , but it has the disadvantage that it is ...