Search results
Results from the WOW.Com Content Network
In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...
The advantages of a Uniform Swimming Pool, Spa and Hot Tub Code, [1] acceptable in various jurisdictions, had long been recognized, prompting IAPMO to pass a resolution at its 1975 annual business conference that directed the president to form a committee to develop a basic swimming pool, spa and hot tub document.
The addition is a 3 ⁄ 16-inch (4.8 mm) diameter round or U-shaped ground pin, 1 ⁄ 8 in (3.2 mm) longer than the power blades (so the device is grounded before the power is connected) and located from them by 1 ⁄ 4 in (6.4 mm) edge-to-edge or 15 ⁄ 32 in (11.9 mm) center-to-center.
The failure of a neutral fuse would cut off power flow through the affected circuit, but the hot conductor could still remain hot relative to ground, an unexpected and potentially hazardous situation. Because of the presence of a neutral fuse, and in the event that it blew, the neutral conductor could not be relied on to remain near ground ...
A spacing of 0.05 inch (1.27 mm) is the most usual, allowing for a two-row connector with a pin spacing of 0.1 inch (2.54 mm). These types are used for many types of equipment, in particular for interconnections within an enclosure. For personal computers, this size was used in floppy-disk-drive cables and older or custom Parallel ATA cables.
A full-load wire does heat up slightly due to the metallic resistance of the wire, but this wire heating is factored into the cable's temperature rating. (NEC 310.10) [ 12 ] The NEC specifies acceptable numbers of conductors in crowded areas such as inside conduit, referred to as the fill rating .
The City of Los Angeles also created an ordinance creating the Office of Plumbing Inspector as part of the city's Board of Health in 1887 [2] Later the City of Los Angeles adopted Ordinance No. 1656 May 1, 1893 [3] which established an examining board for master plumbers, registration of master and journeyman plumbers, requiring approval of the ...
The three service conductors—two 'hot' lines and one neutral—can be seen coming in at the top. The neutral wire is connected to the neutral busbar to the left with all the white wires, and the two hot wires are attached to the main breaker. Below the main breaker are the two bus bars carrying the current between the main breaker and the two ...