enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Electrocardiography in myocardial infarction - Wikipedia

    en.wikipedia.org/wiki/Electrocardiography_in...

    The 2018 European Society of Cardiology/American College of Cardiology Foundation/American Heart Association/World Health Federation Universal Definition of Myocardial Infarction for the ECG diagnosis of the ST segment elevation type of acute myocardial infarction require new ST elevation at J point of at least 1mm (0.1 mV) in two contiguous leads with the cut-points: ≥1 mm in all leads ...

  3. ST depression - Wikipedia

    en.wikipedia.org/wiki/ST_depression

    Also, it can be a normal variant or artifacts, such as: Pseudo-ST-depression, which is a wandering baseline due to poor skin contact of the electrode [3] Physiologic J-junctional depression with sinus tachycardia [3] Hyperventilation [3] Horizontal ST depression in V4, V5, V6 leads during a cardiac stress ECG. Other, non-ischemic, causes include:

  4. Diagnosis of myocardial infarction - Wikipedia

    en.wikipedia.org/wiki/Diagnosis_of_myocardial...

    In particular, acute myocardial infarction in the distribution of the circumflex artery is likely to produce a nondiagnostic ECG. [10] The use of additional ECG leads like right-sided leads V3R and V4R and posterior leads V7, V8, and V9 may improve sensitivity for right ventricular and posterior myocardial infarction. [citation needed]

  5. Electrocardiography - Wikipedia

    en.wikipedia.org/wiki/Electrocardiography

    In a 12-lead ECG, all leads except the limb leads are assumed to be unipolar (aVR, aVL, aVF, V 1, V 2, V 3, V 4, V 5, and V 6). The measurement of a voltage requires two contacts and so, electrically, the unipolar leads are measured from the common lead (negative) and the unipolar lead (positive).

  6. Cardiac monitoring - Wikipedia

    en.wikipedia.org/wiki/Cardiac_monitoring

    Cardiac monitoring generally refers to continuous or intermittent monitoring of heart activity to assess a patient's condition relative to their cardiac rhythm.Cardiac monitoring is usually carried out using electrocardiography, which is a noninvasive process that records the heart's electrical activity and displays it in an electrocardiogram. [1]

  7. ST elevation - Wikipedia

    en.wikipedia.org/wiki/ST_elevation

    An ST elevation is considered significant if the vertical distance inside the ECG trace and the baseline at a point 0.04 seconds after the J-point is at least 0.1 mV (usually representing 1 mm or 1 small square) in a limb lead or 0.2 mV (2 mm or 2 small squares) in a precordial lead. [2] The baseline is either the PR interval or the TP interval ...

  8. Right axis deviation - Wikipedia

    en.wikipedia.org/wiki/Right_axis_deviation

    Quadrant Method: [19] Leads I and II are usually observed. If lead I is positive (translating to 0° on the hexaxial reference system) and lead II is positive (translating to 60°), the electrical heart axis is estimated to fall in the left lower quadrant within the normal range. On the other hand, as shown in Figure 2, if lead I is negative ...

  9. Signal-averaged electrocardiogram - Wikipedia

    en.wikipedia.org/wiki/Signal-averaged...

    Still, the real predictive value of these findings is questioned. Late potentials may be found in 0-10% of normal volunteers. When used as a prognostic factor for the development of ventricular tachycardia, they have a sensitivity of 72% and a specificity of 75%, yielding a positive predictive value of 20% and a negative predictive value of 20%.