Search results
Results from the WOW.Com Content Network
Aircraft often use 400 Hz power internally, so 50 Hz or 60 Hz to 400 Hz frequency conversion is needed for use in the ground power unit used to power the airplane while it is on the ground. Conversely, internal 400 Hz internal power may be converted to 50 Hz or 60 Hz for convenience power outlets available to passengers during flight.
In an alternating current (AC) electric power system, synchronization is the process of matching the frequency, phase and voltage of a generator or other source to an electrical grid in order to transfer power. If two unconnected segments of a grid are to be connected to each other, they cannot safely exchange AC power until they are synchronized.
A regular AC non-simultaneous motor usually can be used as a generator, without any changes to its parts. Induction generators are useful in applications like minihydro power plants, wind turbines, or in reducing high-pressure gas streams to lower pressure, because they can recover energy with relatively simple controls.
An induction generator draws reactive excitation current from an external source. Induction generators have an AC rotor and cannot bootstrap using residual magnetization to black start a de-energized distribution system as synchronous machines do. Power factor correcting capacitors can be added externally to neutralize a constant amount of the ...
[citation needed] Until about 1880, the paradigm for AC power transmission from a high voltage supply to a low voltage load was a series circuit. [citation needed] Open-core transformers with a ratio near 1:1 were connected with their primaries in series to allow use of a high voltage for transmission while presenting a low voltage to the lamps.
Due to high cost of a generator, a set of sensors and limiters will trigger the alarm when the generator approaches the capability-set boundary and, if no action is taken by the operator, will disconnect the generator from the grid. [3] D-curve expands with cooling. The D-curve for a particular generator can be expanded by improved cooling.
For premium support please call: 800-290-4726 more ways to reach us
At each 90-degree rotation, the voltage output polarity is switched from one direction to the other. Therefore, there are 4 cycles of the AC output in one rotation. As the 4 coils are wired in series and their outputs are "in phase", the AC output of this single-phase generator will have 4 times the voltage of that generated by each individual ...