    en.wikipedia.org/wiki/R-value_(insulation)

    Installed faced fiberglass batt insulation with its R-value visible (R-21) [1]. The R-value (in K⋅m 2 /W) is a measure of how well a two-dimensional barrier, such as a layer of insulation, a window or a complete wall or ceiling, resists the conductive [2] flow of heat, in the context of construction. [3]

  3. Structural insulated panel - Wikipedia

    en.wikipedia.org/wiki/Structural_insulated_panel

    EPS is the most common of the foams used and has an R-value (thermal resistance) of about 4 °F·ft 2 ·h/Btu (equivalent to about 0.7 K·m 2 /W) per 25 mm thickness, which would give the 3.5 inches (89 mm) of foam in a 4.5-inch-thick (110 mm) panel an R value of 13.8 (caution: extrapolating R-values over thickness may be imprecise due to non ...

  4. Rigid panel - Wikipedia

    en.wikipedia.org/wiki/Rigid_panel

    A multi-family residential building under construction with rigid panel exterior insulating sheathing. Rigid panel insulation, also referred to as continuous insulation, [1] can be made from foam plastics such as polyurethane (PUR), polyisocyanurate (PIR), and polystyrene, or from fibrous materials such as fiberglass, rock and slag wool.

  5. Insulated siding - Wikipedia

    en.wikipedia.org/wiki/Insulated_siding

    Producers report an average R-value of 2.0 - 5.5, significantly more than that of other siding products including fiber cement, brick and stucco. Homeowners also report insulated siding serves as a noise barrier to external sound. Insulated vinyl siding with added fan fold foam board insulation raises the R-value to 3.5 - 7.5.

  6. Building insulation - Wikipedia

    en.wikipedia.org/wiki/Building_insulation

    For example, in the US the insulation standard for attics, is recommended to be at least R-38 US units, (equivalent to R-6.7 or a U value of 0.15 in SI units). [5] The equivalent standard in the UK are technically comparable, the approved document L would normally require an average U value over the roof area of 0.11 to 0.18 depending on the ...

  7. Building insulation material - Wikipedia

    en.wikipedia.org/wiki/Building_insulation_material

    Closed-cell foams are superior insulators. While open-cell foams typically have R-values of 3 to 4 per inch (RSI-0.53 to RSI-0.70 per inch), closed-cell foams can attain R-values of 5 to 8 per inch (RSI-0.88 to RSI-1.41 per inch). This is important if space is limited, because it allows a thinner layer of insulation to be used.

  8. AOL Mail

    mail.aol.com

    Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!

  9. Superinsulation - Wikipedia

    en.wikipedia.org/wiki/Superinsulation

    The easiest way is often to add layers of continuous rigid exterior insulation, [7] and sometimes by building new exterior walls that allow more space for insulation. A vapor barrier can be installed outside the original framing but may not be needed. An improved continuous air barrier is almost always worth adding, as older homes tend to be ...